PL-C PRECISE-LOG Current Data Logger
Click Image for Gallery
PL-C is an 8-channel, battery-powered, standalone current data logger. The logger records eight external current sources and saves data in 8-MB memory.
Its aluminum enclosure makes it excellent in the harshest industrial environment.
16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical.
Simply plug the logger into the computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more…
Features:
- 16-bit analog-to-digital converter
- 8-megabyte memory size
- USB interface with baud rate of 115200 bps
- Programmable input ranges (20 mA, 50 mA)
- Over ten years of battery life
- Powerful software for configuration, downloading, plotting, analysis and alarm reporting
- Wide sampling interval selections (one second to 12 hours)
- Rugged aluminum enclosure
Documents:
General | |
---|---|
Product Name | PRECISE-LOG Current Data Logger |
Model | PL-C |
Inputs | |
Connection | Plugable terminal block for eight external channels |
Channels | Eight external current DC. Programmable input selections for each external channel: 4 ~ 20 mA 0 ~ 50 mA |
Resolution | 0.0018% |
Accuracy | ±0.1% FSR @ 25 °C |
Load Resistor | 12 Ohms |
Over-Current Protection | Up to ± 100 mA |
Alarms | |
Channel Alarms | Two editable alarm thresholds per channel. |
Alarm Indicator | On-board LED becomes red when in alarm condition. |
On-board Memory | |
Size | 8 Mega bytes (4MB readings). |
Data Retention | Over 20 years. |
Sampling | |
Sampling Interval | 1 second to 12 hours user selectable. |
Logging Mode | Stop recording or FIFO when memory is full. |
Logging Activation | Programmable instant, start delay or field push button activation. |
Communications | |
Interface | USB (Mini-USB-B) (USB-A-mini USB-B Cable included) |
Baud Rate | 115200 bps. |
Battery | |
Power | Built-in 3.6V Lithium Battery. |
Battery Life | 10 years based on 1 minute sampling interval in stand-alone mode. |
Software | |
SiteView (Sold separately) | Configuration, downloading, plotting, real-time view, custom calibration and custom equation. |
Software Requirement | Computer with 1.0 GHz or faster processor 1 GB Memory or higher 10 GB of available hard-drive space or higher Windows XP with SP2 or later, Vista, Window 7,8,10, 11 At least one USB port or one COM port. |
Physical | |
Material | Aluminum enclosure. |
Dimension | 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches). |
Weight | 200g |
Mounting | Probe/wall-mount holes for hanging/mounting. |
Others | |
LED Indicator | Tri-Color LED: (can be disabled for power saving) Normal Sampling: light green when sampling. Alarm: red when sampling. Low Battery: amber when sampling. |
Operating Environment | -40 ~ +70 °C (-40 °F ~ 158 °F), 0 ~ 95% RH non-condensing. |
Clock Accuracy | ±1 mintue per month. |
Approval | CE, FCC |
Logger Memory Capacity
Sampling Interval | Enabled Channel | Logging Capacity |
---|---|---|
1 minute | 1 | 8 years |
1 minute | 2 | 4 years |
1 minute | 8 | 1 year |
10 seconds | 1 | 485 days |
10 seconds | 2 | 242 days |
10 seconds | 8 | 60 days |
1 second | 1 | 48 days |
1 second | 2 | 24 days |
1 second | 8 | 6 days |