PL-T PRECISE-LOG 8-Channel Thermocouple Data Logger
The PRECISE-LOG PL-T is an 8-channel, battery-powered, standalone thermocouple data logger designed for industrial, laboratory, research, testing, and long-term temperature-monitoring applications.
The logger provides:
- 8 external thermocouple input channels
- 1 onboard thermistor temperature channel
- Built-in cold-junction compensation
- USB communication
- 8 MB non-volatile flash memory
- Long-term standalone operation
Each external channel can be independently configured for the required thermocouple type and input range.
The onboard thermistor measures ambient temperature and provides cold-junction compensation for accurate thermocouple measurement.
The PL-T is the non-WiFi version of the PRECISE-LOG thermocouple platform and is well suited to applications where standalone recording, direct USB communication, or network access through Smart-Hub is required.
Multi-Channel Thermocouple Measurement
The PL-T provides eight external thermocouple channels for multi-point temperature monitoring.
Two programmable voltage ranges are available:
- −8 mV to +73 mV
- −2 mV to +18 mV
Depending on the selected range, the logger supports thermocouple types:
- B
- C
- E
- J
- K
- N
- R
- S
- T
Each channel can be independently enabled and configured through SiteView.
This allows different thermocouple types or temperature ranges to be used within the same data-logging system.
Cold-Junction Compensation
The PL-T includes an onboard thermistor that measures ambient temperature from:
−40°C to +70°C (−40°F to +158°F)
The onboard temperature channel is used for cold-junction compensation, allowing the logger to compensate thermocouple measurements for the temperature at the logger terminals.
The onboard thermistor accuracy is:
±0.2°C from 0°C to 70°C.
High-Resolution Data Logging
The PL-T uses a 16-bit analog-to-digital converter with a measurement resolution of:
0.0018%
This provides high-resolution temperature measurement for laboratory, industrial, research, validation, and testing applications.
Sampling intervals are programmable from:
1 second to 12 hours.
Standalone Operation and Long-Term Recording
The PL-T operates independently after configuration and stores measurements in 8 MB of non-volatile flash memory.
The memory provides storage for approximately 4 million readings and retains recorded data for more than 20 years.
Logging can be configured for:
- Immediate start
- Delayed start
- Field push-button activation
When memory becomes full, the logger can either:
- Stop recording, or
- Continue recording in FIFO mode
The built-in 3.6 V lithium battery provides up to approximately 10 years of operation at a 1-minute sampling interval in standalone mode, depending on operating conditions and configuration.
USB Communication and SiteView Software
The PL-T connects directly to a Windows PC through its Plug & Play USB interface.
SiteView software provides tools for:
- Configuring thermocouple channels
- Selecting thermocouple types
- Selecting input ranges
- Configuring logging sessions
- Downloading recorded data
- Viewing real-time temperatures
- Displaying graphs and tables
- Configuring alarm thresholds
- Applying custom calibration
- Applying custom equations
- Exporting and analyzing recorded data
For local operation, SiteView communicates directly with the PL-T through USB.
For network applications, the PL-T can be connected to a Smart-Hub and accessed remotely by supported Microedge software.
Alarm Functions
The PL-T provides configurable alarm functions for temperature-monitoring applications.
Each channel supports two programmable alarm thresholds.
The onboard tri-color status LED provides visual indication of:
- Normal sampling
- Alarm condition
- Low battery
The LED can be disabled to reduce power consumption.
Remote Access and Network Integration
Although the PL-T is a USB-based data logger, it can also be accessed remotely over an Ethernet network by connecting it to a Microedge Smart-Hub.
Smart-Hub acts as a communication gateway and allows connected USB data loggers to be accessed through:
- SiteView
- SiteView-Web
- SiteView SDK
- Pluto
Smart-Hub also provides:
- RESTful Web API
- Modbus TCP Gateway
This allows PL-T temperature data to be integrated with third-party software, PLCs, HMIs, SCADA systems, and other industrial monitoring platforms.
Unlike the PL-TW, the PL-T does not contain a built-in WiFi interface and does not operate directly as a Modbus TCP server. Network and Modbus TCP access for the PL-T is provided through Smart-Hub.
Rugged Industrial Design
The PL-T is housed in a durable aluminum enclosure designed for laboratory, industrial, and field applications.
Its operating environment is:
−40°C to +70°C (−40°F to +158°F)
and:
0–95% RH, non-condensing.
KEY FEATURES
8 External Thermocouple Channels
Provides multi-point temperature measurement using independently configurable thermocouple inputs.Onboard Temperature Channel
Built-in thermistor monitors ambient temperature and provides cold-junction compensation.Multiple Thermocouple Types
Supports B, C, E, J, K, N, R, S, and T thermocouples depending on the selected input range.Two Programmable Input Ranges
Supports −8 to +73 mV and −2 to +18 mV ranges.16-Bit Data Resolution
Provides 0.0018% measurement resolution.8 MB Non-Volatile Flash Memory
Stores approximately 4 million readings for long-term standalone recording.1 Second to 12 Hour Sampling
Wide programmable sampling interval selection for short-term testing and long-term monitoring.Long Battery Life
Up to approximately 10 years at a 1-minute sampling interval in standalone operation.USB Communication
Provides direct local communication with SiteView.SiteView Software Support
Provides logger configuration, data download, real-time monitoring, plotting, calibration, custom equations, alarm configuration, and data analysis.Programmable Alarm Thresholds
Two configurable alarm thresholds are available for each channel.Flexible Logging Modes
Supports immediate start, delayed start, field push-button activation, stop-on-full, and FIFO operation.Remote Network Access through Smart-Hub
Smart-Hub provides Ethernet access for SiteView, SiteView-Web, SiteView SDK, and Pluto.RESTful Web API Integration
Through Smart-Hub, PL-T data can be accessed by compatible third-party software.Modbus TCP Gateway Integration
Smart-Hub can expose connected PL-T data through Modbus TCP for integration with PLCs, HMIs, SCADA systems, and other Modbus TCP masters.Rugged Aluminum Enclosure
TYPICAL APPLICATIONS
The PL-T is suitable for:
- Multi-point temperature monitoring
- Industrial process temperature monitoring
- Laboratory testing
- Research
- Product validation
- Environmental chambers
- Equipment testing
- Oven and furnace monitoring
- HVAC temperature monitoring
- Manufacturing processes
- Thermal testing
- Temperature profiling
- Long-term unattended temperature logging
- Remote temperature monitoring through Smart-Hub
- PLC / SCADA temperature monitoring through Smart-Hub
DOCUMENTS
| General | |
|---|---|
| Product Name | PL-T PRECISE-LOG 8-Channel Thermocouple Data Logger |
| Model | PL-T |
| External Channels | 8 thermocouple channels |
| Internal Channel | 1 onboard thermistor |
| Inputs | |
| Connection | Pluggable terminal block for 8 external channels |
| External Inputs | 8 thermocouple channels |
| Onboard Temperature | −40°C to +70°C (-40°F ~ 158°F) |
| Programmable Range 1 | −8 mV to +73 mV |
| Programmable Range 2 | −2 mV to +18 mV |
| Resolution | 0.0018% |
| Thermistor Accuracy | ±0.2°C from 0°C to 70°C |
| Thermocouple Accuracy | ±0.1% to ±0.2% plus thermocouple accuracy |
| Cold-Junction Compensation | Onboard thermistor |
| Overvoltage Protection | Up to ±20 VDC |
| Alarms | |
| Channel Alarm Thresholds | Two programmable alarm thresholds per channel |
| Alarm Indicator | Status LED flashes red during sampling when an alarm condition is active |
| On-board Memory | |
| Flash Memory | 8 MB (4MB readings) non-volatile flash memory |
| Data Retention | More than 20 years. |
| Memory-Full Options | Stop logging or FIFO mode |
| Sampling and Logging | |
| Sampling Interval | Programmable from 1 second to 12 hours |
| Logging Modes | Stop when memory is full or continue in FIFO mode |
| Logging Activation | Immediate start, delayed start, or field push-button activation |
| Communications | |
| USB Interface | Mini-USB-B |
| Included USB Cable | USB-A to Mini-USB-B |
| Communication Rate | 115200 bps |
| Battery and Power | |
| Internal Battery | Built-in 3.6 V lithium battery |
| Battery Life | Up to approximately 10 years at a 1-minute sampling interval in standalone mode |
| Software | |
| Software | SiteView (Sold separately) |
| Functions | Configuration, downloading, plotting, real-time monitoring, custom calibration and custom equations |
| Local Communication | USB |
| Computer Requirement | 1.0 GHz or faster processor; 1 GB RAM or higher; 10 GB available storage or higher |
| Required Interface | At least one available USB port |
| Physical Specifications | |
| Enclosure Material | Aluminum |
| Dimension | 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches) |
| Weight | 200g |
| Mounting | Integrated holes for wall or equipment mounting |
| LED Indicators | |
| The tri-color status LED can be disabled to reduce power consumption. | |
| Green Indication | Normal sampling |
| Red Indication | Alarm condition |
| Amber Indication | Low battery |
| Operating Environment | |
| Operating Temperature | -40 ~ +70 °C (-40 °F ~ 158 °F) |
| Operating Humidity | 0 ~ 95% RH, non-condensing |
| Clock Accuracy | ±1 mintue per month |
| Approval | CE, FCC |
Logger Memory Capacity
| Sampling Interval | Enabled Channel | Logging Capacity |
|---|---|---|
| 1 minute | 1 | 8 years |
| 1 minute | 2 | 4 years |
| 1 minute | 8 | 1 year |
| 10 seconds | 1 | 485 days |
| 10 seconds | 2 | 242 days |
| 10 seconds | 8 | 60 days |
| 1 second | 1 | 48 days |
| 1 second | 2 | 24 days |
| 1 second | 8 | 6 days |
Programmable Channel Range Specifications:
| Range: -8mV ~ +73mV Accuracy: ±0.1% (0.08 mV)@ 25°C + Temperature Compensation Accuracy | |||
|---|---|---|---|
| Thermocouple Type | Temperature Range (°C) | Resolution (°C) | Accuracy (°C) |
| Type E | -171 to +955 | 0.02 | 0.56 |
| Type J | -205 to +1200 | 0.027 | 0.73 |
| Type K | -270 to +1372 | 0.04 | 1.07 |
| Type N | -270 to +1300 | 0.045 | 1.21 |
| Type T | -270 to +400 | 0.037 | 1.00 |
| Type C | 0 to 2320 | 0.1 | 2.5 |
| Type S | -50 to 1768 | 0.04 | 3.85 |
| Range: -2mV ~ +18mV Accuracy: ±0.15% (0.03 mV) @ 25°C + Temperature Compensation Accuracy | |||
| Type E | -35 to 260 | 0.005 | 0.45 |
| Type J | -40 to 330 | 0.0062 | 0.56 |
| Type K | -53 to 437 | 0.0082 | 0.74 |
| Type N | -81 to 532 | 0.01 | 0.92 |
| Type T | -55 to 353 | 0.008 | 0.62 |
| Type B | 0 to 1820 | 0.03 | 3.95 |
| Type R | -50 to 1539 | 0.026 | 2.62 |
| Type S | -50 to 1704 | 0.03 | 2.9 |
| Type C | 0 to 986 | 0.0164 | 1.65 |
Resources: