LPMB-1 SITE-LOG High Accuracy Voltage, Current and Temperatrue Data Logger

LPMB-1 SITE-LOG High Accuracy Voltage, Current and Temperatrue Data Logger

The SITE-LOG LPMB-1 is a 7-channel, battery-powered, standalone high-accuracy voltage and current data logger designed for industrial, laboratory, research, testing, and process-monitoring applications.

The logger provides:

  • 4 voltage input channels
  • 3 current input channels
  • 1 onboard temperature channel

The voltage channels support programmable ranges of:

  • 0 to 20 VDC
  • −5 to +5 VDC

The current channels support:

  • 4–20 mA
  • 0–50 mA

Input signals can come from sensors, transducers, transmitters, process instruments, batteries, power supplies, and other compatible voltage or current sources. 

The onboard temperature channel monitors ambient temperature and provides temperature compensation for improved measurement performance.

Recorded data is stored in 8 MB of non-volatile flash memory, providing long-term standalone data recording without requiring a continuously connected computer.

High-Accuracy Voltage and Current Measurement

The LPMB-1 is designed for applications where both voltage and current signals must be recorded by the same instrument.

Channels 1 through 4 are dedicated to voltage measurement, while channels 5 through 7 are dedicated to current measurement.

The logger uses a 16-bit analog-to-digital converter, providing a resolution of 0.0018%.

Onboard Temperature Monitoring and Compensation

The built-in thermistor measures ambient temperature from:

−40°C to +70°C (−40°F to +158°F)

with an accuracy of:

±0.2°C from 0°C to 70°C

The onboard temperature measurement can be recorded along with the external channels and is also used for temperature compensation.

High-Resolution Data Logging

The LPMB-1 uses a 16-bit ADC for high-resolution voltage and current measurements.

Sampling intervals are programmable from:

20 milliseconds to 12 hours

An external power supply is required when the sampling interval is less than 5 seconds. 

This wide sampling range allows the same logger to support both relatively fast testing and long-term monitoring.

Standalone Operation and Long-Term Recording

The LPMB-1 operates independently after configuration and stores measurements in 8 MB of onboard non-volatile flash memory.

The memory provides storage for approximately 4 million readings and retains data for more than 20 years. 

Logging can be started by:

  • Immediate start
  • Programmable delayed start
  • Field push-button activation

When memory becomes full, the logger can be configured to:

  • Stop recording, or
  • Continue recording in FIFO mode

The internal lithium battery provides up to approximately 10 years of operation at a 1-minute sampling interval, depending on operating conditions and configuration. 

USB Communication and SiteView Software

The LPMB-1 connects directly to a Windows PC through its Plug & Play USB interface.

SiteView software provides tools for:

  • Configuring input channels
  • Selecting voltage and current ranges
  • Configuring logging sessions
  • Downloading recorded data
  • Viewing real-time measurements
  • Displaying graphs and tables
  • Configuring alarm thresholds
  • Applying custom calibration
  • Applying custom equations
  • Converting voltage and current signals into engineering units
  • Exporting and analyzing recorded data

The LPMB-1 also provides an AUX TTL-level serial communication interface with automatic baud-rate detection from 2400 to 115200 bps. 

Alarm and Excitation Control

The LPMB-1 provides configurable alarm and control functions for applications requiring more than basic data recording.

Each channel supports two programmable alarm thresholds.

The available output terminals can be configured for:

  • Alarm output
  • Excitation control

The onboard status LED provides visual indication of normal sampling, alarm conditions, and low battery status. 

Remote Access and Network Integration

The LPMB-1 can be connected to a Microedge Smart-Hub for remote access over an Ethernet network.

Smart-Hub functions as a USB Device Server, allowing the LPMB-1 to be accessed remotely by:

  • SiteView
  • SiteView-Web
  • SiteView SDK
  • Pluto

Smart-Hub can also provide:

  • RESTful Web API
  • Modbus TCP Gateway

This allows LPMB-1 measurements to be incorporated into remote monitoring systems and third-party industrial applications.

Rugged Industrial Design

The LPMB-1 uses a durable aluminum enclosure and a conformal-coated circuit board for additional protection against:

  • Moisture
  • Corrosion
  • Mildew

The logger is designed for operation from:

−40°C to +70°C (−40°F to +158°F)

at:

0–95% RH, non-condensing. 


KEY FEATURES

  • 7 External Measurement Channels
    Four voltage channels and three current channels allow voltage and current signals to be monitored by the same logger.

  • Onboard Temperature Channel
    Built-in thermistor provides ambient-temperature monitoring and temperature compensation.

  • Programmable Voltage Ranges
    Voltage channels support 0–20 VDC and −5 to +5 VDC ranges.

  • Programmable Current Ranges
    Current channels support 4–20 mA and 0–50 mA signals.

  • 16-Bit Data Resolution
    High-resolution ADC provides 0.0018% measurement resolution.

  • 8 MB Non-Volatile Flash Memory
    Stores approximately 4 million measurements for long-term standalone recording.

  • Wide Sampling Interval Selection
    Programmable from 20 milliseconds to 12 hours.

  • Long Battery Life
    Up to approximately 10 years at a 1-minute sampling interval.

  • USB Communication
    Plug & Play USB provides direct communication with SiteView.

  • TTL-Level Serial Communication
    AUX interface supports automatic baud-rate detection from 2400 to 115200 bps.

  • SiteView Software Support
    Provides configuration, data download, real-time monitoring, plotting, calibration, custom equations, alarms, and analysis.

  • Alarm and Excitation Control
    Supports programmable alarm thresholds, MOSFET alarm outputs, and excitation control.

  • Programmable Warm-Up Delay
    Excitation warm-up delay can be configured from 10 to 240 seconds.

  • Flexible Logging Modes
    Supports immediate start, delayed start, field push-button activation, stop-on-full, and FIFO recording.

  • Remote Network Access
    Connect to Smart-Hub for remote access through SiteView, SiteView-Web, SiteView SDK, and Pluto.

  • RESTful API and Modbus TCP Integration
    Smart-Hub provides interfaces for integration with compatible third-party software and industrial systems.

  • Rugged Aluminum Enclosure

  • Conformal-Coated PCB


TYPICAL APPLICATIONS

The LPMB-1 is suitable for:

  • 4–20 mA transmitter monitoring
  • 0–50 mA current measurement
  • Voltage signal recording
  • Process instrumentation
  • Pressure transmitters
  • Flow transmitters
  • Level transmitters
  • Environmental sensors
  • Industrial sensor monitoring
  • Battery and power-supply monitoring
  • Laboratory testing
  • Product validation
  • Research
  • Equipment monitoring
  • Long-term process data acquisition

DOCUMENTS




General
Product Name SITE-LOG High Accuracy Voltage, Current and Temperature Data Logger
Model LPMB-1
Inputs
External Channels 7
Voltage Channels CH1 - CH4
Current Channels CH5 - CH7
Internal Channel Onboard thermistor
Connection Pluggable terminal block for seven external channels, excitation control and alarm outputs
Voltage Channels
Channels CH1 - CH4
Programmable Ranges 0–20 VDC; −5 to +5 VDC
Resolution >0.0018%
Accuracy >±0.05% FSR @ 25°C
Input Impedance >1 MΩ
Overvoltage Protection >Up to ±40 VDC
Current Channels
Channels CH5 - CH7
Programmable Ranges >4–20 mA; 0–50 mA
Resolution >0.0018%
Accuracy >±0.1% FSR @ 25°C
Load Resistor 12 Ω
Over-Current Protection >Up to ±100 mA
Onboard Thermistor Channel
Resolution >0.0018%
Range −40°C to +70°C (-40°F ~ 158°F)
Accuracy >±0.2°C from 0°C to 70°C
Alarm Functions
Channel Alarm Thresholds Two programmable alarm thresholds per channel
Alarm Outputs ALARM1 and A2/E terminals can be configured as alarm outputs
Alarm Output Type N-channel MOSFET switch
Alarm ON MOSFET switch ON
Alarm OFF MOSFET switch OFF
Maximum Alarm Output 200mA @ 24 VDC
Alarm Delay Programmable from 0 to 10 minutes in 1-minute increments
Alarm Indicator Status LED flashes red during sampling when an alarm condition is active
On-board Memory
Flash Memory 8 MB (4MB readings) non-volatile flash memory
Data Retention More than 20 years.
Memory-Full Options Stop logging or FIFO mode
Sampling and Logging
Sampling Interval Programmable from 20 milliseconds to 12 hours
Maximum number of enabled channels:
20 ms sampling interval: 1 channel
30 ms sampling interval: 2 channels
40 ms or longer sampling interval: up to 8 channels
An external power supply is required when the sampling interval is less than 1 second.
Fast Sampling Power Requirement External power is required when the sampling interval is less than 1 second
Logging Modes Stop when memory is full or continue in FIFO mode
Logging Activation Immediate start, delayed start, or field push-button activation
Communications
USB Interface Mini-USB-B
USB Cable USB-A to Mini-USB-B cable included
AUX Interface RJ11 TTL level serial communication
Baud Rate Automatically detected from 2400 to 115200 bps on USB and AUX interfaces
Remote Network Access Available through Microedge Smart-Hub
Battery and Power
Internal Battery Built-in 3.6V Lithium Battery.
Battery Life Up to 10 years at a 1-minute sampling interval, depending on usage and operating conditions
External Power 5 VDC through USB
Software
Software SiteView (Sold separately)
Functions Logger configuration, data download, graphing, real-time monitoring, custom calibration, custom equations, alarm configuration, and data analysis
Operating Systems Windows 8, 10 and 11
Computer Requirement 1.0 GHz or faster processor; 1 GB RAM or higher; 10 GB available storage or higher
Required Interface At least one available USB port
Physical Specifications
Enclosure Material Aluminum
PCB Protection Conformal coating.
Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches)
Weight 200g
Mounting Integrated holes for wall or equipment mounting
LED Indicators
The tri-color status LED can be disabled to reduce power consumption.
Green Indication Normal sampling
Red Indication Alarm condition
Amber Indication Low battery
Excitation Control
The A2/E terminal can be configured as an excitation-control output for controlling power to an externally powered sensor or device. The excitation warm-up delay is programmable from: 10 to 240 seconds in 10-second increments
Operating Environment
Operating Temperature -40 ~ +70 °C (-40 °F ~ 158 °F)
Operating Humidity 0 ~ 95% RH, non-condensing
Clock Accuracy ±1 mintue per month
Approval CE, FCC

Logger Memory Capacity

Sampling Interval Enabled Channel Logging Capacity
1 minute 1 8 years
1 minute 2 4 years
1 minute 8 1 year
10 seconds 1 485 days
10 seconds 2 242 days
10 seconds 8 60 days
1 second 1 48 days
1 second 2 24 days
1 second 8 6 days
100 milliseconds 1 4 days
100 milliseconds 2 2 days
100 milliseconds 8 14.4 hours

SiteView accesses data loggers

SiteView-Web accesses data loggers

Pluto WebServer accesses data loggers

  • $638.00(USD)

Tags: voltage data logger, current data logger, voltage current logger, 7 channel data logger, multi-channel data logger, 4-20mA data logger, 4-20mA recorder, 0-50mA logger, 0-20V data logger, ±5V data logger, process signal logger, transmitter data logger, industrial data logger, USB data logger, LPMB-1, SITE-LOG