iTC-80 iLOG Thermocouple and Temperature Data Logger

iTC-80 iLOG Thermocouple and Temperature Data Logger

iLog Thermocouple Data Logger is low-cost, high-accuracy, battery-powered, stand-alone thermocouple + ambient temperature data logger. The logger records up to 8 megabytes of data and stores them in non-volatile flash memory for later retrieval. 

iLog Thermocouple Data Logger measures wide range of temperatures and works with the following thermocouples: E, J, K, N, T, C. 

Its on-board temperature channel provides environment monitoring and Cold-Junction compensation. 

Its aluminum enclosure makes it excellent in the harshest industrial environment. Plug & Play USB port, and versatile custom equation simplify communications and engineering unit conversion. 

16-bit ADC makes it well suited for science and laboratory applications where precise and accurate measurements are critical. 

Simply plug the logger into the computer's USB port, and the software automatically recognizes it and handles the configuration, downloading, graph viewing and more... 

Features:

    • 16-bit analog-to-digital converter
    • Cold-Junction Compensation
    • 8-megabyte memory size
    • Both USB and serial interfaces with auto baud rate of up to 115200 bps
    • Over 12 years of battery life
    • Powerful software for configuration, downloading, plotting, analysis and alarm reporting
    • Configurable alarm controls/excitation controls
    • Wide sampling interval selections (20 milliseconds to 12 hours)
    • Rugged aluminum enclosure

    Documents:

    iLOG Thermocouple Data Logger Specifications

    SiteView Specifications


    Want to remotely access this data logger? Check out DSS-2 Site USB Device Server


    General
    Product Name iLog Thermocouple Data Logger
    Model iTC-80
    Inputs
    Connection Plugable terminal block for one external channels, excitation controls and alarm outputs
    Channels One on-board thermistor temperature (-40°C ~ 70°C, -40°F ~ 158°F)
    One external thermocouple channel:-8mV ~ +73mV
    Resolution 0.0018%
    Accuracy Thermistor: ±0.2°C(0°C ~ 70°C, 32°F ~ 158°F)
    Thermocouple: ±0.1% ~ 0.2% + T/C Accuracy
    Over-voltage Protection Up to -3VDC ~ +40VDC
    Alarms
    Channel Alarms Two editable alarm thresholds per channel.
    Alarm Output ALARM1 & A2/E terminal strips can be configured as alarm outputs.
    Alarm-On: MOSFET(N-Channel) switch on
    Alarm-Off: MOSFET(N-Channel) switch off
    Max Power: 200mA @ 24VDC
    Alarm-On Delay Programmable 0 - 10 minutes delay with 1-minute increment.
    Alarm Indicator On-board LED becomes red when in alarm condition.
    On-board Memory
    Size 8 Mega bytes (4 MB readings).
    Data Retention Over 20 years.
    Sampling
    Sampling Interval 20 milliseconds to 12 hours programmable. (external power supply required if in fast sample mode)
    Logging Mode Stop recording or FIFO when memory is full.
    Logging Activation Programmable instant, start delay or field push button activation.
    Communications
    Interface USB (Mini-USB-B) (USB-A-mini USB-B Cable included)
    AUX(RJ11) for TTL level RS232 communications.
    Baud Rate Auto-detect baud rate from 2400 to 115200 bps on both USB and AUX.
    Battery
    Power Built-in 3.6V Lithium Battery.
    Battery Life 10 years based on 1 minute sampling interval.
    Software
    SiteView (Sold separately) Configuration, downloading, plotting, real-time view, custom calibration and custom equation.
    Software Requirement Computer with 1.0 GHz or faster processor
    1 GB Memory or higher
    10 GB of available hard-drive space or higher
    Windows XP with SP2 or later, Vista, Window 7,8,10
    At least one USB port or one COM port.
    Physical
    Material Aluminum enclosure.
    Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches).
    Weight 200g
    Mounting Probe/wall-mount holes for hanging/mounting.
    Others
    LED Indicator Tri-Color LED: (can be disabled for power saving)
    Normal Sampling: light green when sampling.
    Alarm: red when sampling.
    Low Battery: amber when sampling.
    Excitation Control A2/E terminal strip can be configured as excitation control output for driving the power of connected devices.
    Warm-up delay interval settings: 10 to 240 seconds with 10-second increment.
    Operating Environment -40 ~ +70 °C (-40 °F ~ 158 °F), 0 ~ 95% RH non-condensing.
    Clock Accuracy ±1 mintue per month.
    Approval CE, FCC

    Logger Memory Capacity

    Sampling Interval Logging Capacity
    1 minute 2 years
    10 seconds 121 days
    1 second 12 days
    100 milliseconds 14 hours

    Channel Range Specifications:

    Range: -8mV ~ +73mV Accuracy: ±0.1% (0.08 mV)@ 25°C + Temperature Compensation Accuracy
    Thermocouple Type Temperature Range (°C) Resolution (°C) Accuracy (°C)
    Type E -171 to +955 0.02 0.56
    Type J -205 to +1200 0.027 0.73
    Type K -270 to +1372 0.04 1.07
    Type N -270 to +1300 0.045 1.21
    Type T -270 to +400 0.037 1.00
    Type C 0 to 2320 0.1 2.5
    Type S -50 to 1768 0.04 3.85
    • $379.00(USD)

    Tags: iTC-80, thermocouple data logger