All products shipped from Canada to the United States by Microedge Instruments qualify for duty‑free treatment under USMCA/CUSMA.   DETAILS

LPTH-1 SITE-LOG Thermistor and Temperature Data Logger

LPTH-1 SITE-LOG Thermistor and Temperature Data Logger

The LPTH-1 SITE-LOG is a rugged 7-channel thermistor data logger designed for multi-point temperature and resistance monitoring in industrial, laboratory, research, testing, and environmental applications.

It provides seven external thermistor/resistance input channels plus one built-in temperature channel for ambient temperature monitoring. The LPTH-1 is particularly well suited for 10 kΩ NTC thermistors, while SiteView equations allow the logger to support other compatible thermistor and resistance measurement applications.

The LPTH-1 is a battery-powered, standalone logger with 8 MB of non-volatile flash memory, allowing measurements to be recorded in the field and downloaded later through USB. Its rugged aluminum enclosure and conformal-coated PCB provide additional protection for long-term use in demanding environments.

Multi-Channel Thermistor and Resistance Measurement

The LPTH-1 provides seven external channels for connecting thermistors or resistive sensors.

It can be used for applications such as:

  • Multi-point temperature monitoring

  • 10 kΩ NTC thermistor measurement

  • Resistance measurement

  • Laboratory temperature testing

  • Equipment and process monitoring

  • Environmental temperature monitoring

For thermistor applications, SiteView converts the measured resistance into temperature using the selected thermistor equation.

Users can enter known thermistor coefficients or calculate them from temperature-resistance data points.

High-Resolution Data Logging

The LPTH-1 uses a 16-bit analog-to-digital converter for high-resolution measurements.

Sampling intervals are programmable from:

20 milliseconds to 12 hours

This allows the same logger to be used for both fast testing and long-term monitoring.

For sampling intervals below one second, external power is required.

Standalone Operation and Long-Term Recording

Recorded data is stored in 8 MB of onboard non-volatile flash memory and retained even when external power is removed.

Depending on the sampling interval and number of enabled channels, the logger can record from hours to years of data.

The logger supports:

  • Stop logging when memory is full

  • FIFO logging mode

  • Immediate logging

  • Delayed start

  • Field push-button activation

With a 1-minute sampling interval, the internal battery can provide up to 10 years of operation, depending on usage and operating conditions.

USB Communication and SiteView Software

The LPTH-1 connects directly to a computer through USB.

SiteView software provides the tools required to:

  • Configure logging sessions

  • Configure thermistor equations

  • Download recorded data

  • View real-time readings

  • Display data in graph and table formats

  • Configure alarms

  • Apply custom equations and engineering-unit conversions

  • Export and analyze recorded data

SiteView is sold separately.

Alarm and Excitation Control

The LPTH-1 provides configurable alarm and control functions for applications requiring more than basic data recording.

Each channel supports two programmable alarm thresholds.

The available output terminals can be configured for:

  • Alarm output

  • Excitation control

The onboard status LED provides visual indication of normal sampling, alarm conditions, and low battery status.

Remote Access and Network Integration

Although the LPTH-1 is a USB-based data logger, it can also be accessed remotely over an Ethernet network by connecting it to a Microedge Smart-Hub.

Smart-Hub allows the LPTH-1 to be accessed through:

  • SiteView

  • SiteView-Web

  • SiteView SDK

  • Pluto

Smart-Hub also provides:

  • RESTful Web API

  • Modbus TCP Gateway

This allows LPTH-1 thermistor and resistance measurements to be integrated with third-party software, PLCs, HMIs, SCADA systems, and other industrial monitoring platforms.

Smart-Hub Specifications Page

Rugged Industrial Design

The LPTH-1 is housed in a durable aluminum enclosure.

Its circuit board is protected with conformal coating to help resist:

  • Moisture

  • Corrosion

  • Mildew

The logger is designed for operation in environments from:

-40°C to +70°C (-40°F to +158°F)

with up to:

95% RH, non-condensing

Key Features

  • 7 external thermistor/resistance input channels

  • 1 built-in temperature channel

  • Optimized for 10 kΩ NTC thermistors

  • 16-bit analog-to-digital converter

  • 8 MB non-volatile flash memory

  • 20 ms to 12 hr programmable sampling interval

  • USB communication

  • AUX TTL-level serial communication

  • Programmable alarm thresholds

  • Alarm output and excitation control

  • Stop or FIFO logging mode

  • Immediate, delayed, or push-button logging activation

  • Up to 10 years of battery life at a 1-minute sampling interval

  • Rugged aluminum enclosure

  • Conformal-coated PCB

  • SiteView software support

  • Remote Ethernet access through Smart-Hub

  • RESTful Web API and Modbus TCP integration through Smart-Hub

Typical Applications

The LPTH-1 is suitable for:

  • Multi-point temperature monitoring

  • Thermistor sensor testing

  • Laboratory research

  • Environmental monitoring

  • Industrial equipment monitoring

  • Process temperature monitoring

  • Product testing and validation

  • Long-term temperature recording

  • Resistance measurement


Documents: 

SITE-LOG Thermistor Data Logger (LPTH-1) Specifications

SiteView Specifications


General
Product Name SITE-LOG Thermistor Data Logger
Model LPTH-1
Inputs
External Input Channels 7 thermistor/resistance input channels
Built-in Temperature Channel 1 onboard thermistor temperature channel
Input Connection Pluggable terminal block for seven external channels, excitation control, and alarm outputs
Input Resolution 0.0018%
Thermistor Accuracy ±0.2°C from 0°C to 70°C at 25°C, using a 10 kΩ NTC thermistor; thermistor probe error not included
Recommended Thermistor 10 kΩ NTC thermistor
Alarm Functions
Channel Alarm Thresholds Two programmable alarm thresholds per channel
Alarm Outputs ALARM1 and A2/E terminals can be configured as alarm outputs
Alarm Output Type N-channel MOSFET switch
Alarm ON MOSFET switch ON
Alarm OFF MOSFET switch OFF
Maximum Alarm Output 200mA @ 24 VDC
Alarm Delay Programmable from 0 to 10 minutes in 1-minute increments
Alarm Indicator Status LED flashes red during sampling when an alarm condition is active
On-board Memory
Flash Memory 8 MB (4MB readings) non-volatile flash memory
Data Retention More than 20 years.
Memory-Full Options Stop logging or FIFO mode
Sampling and Logging
Sampling Interval Programmable from 20 milliseconds to 12 hours
Fast Sampling Power Requirement External power is required when the sampling interval is less than 1 second
Logging Modes Stop when memory is full or continue in FIFO mode
Logging Activation Immediate start, delayed start, or field push-button activation
Communications
USB Interface Mini-USB-B
USB Cable USB-A to Mini-USB-B cable included
AUX Interface RJ11 TTL level serial communication
Baud Rate Automatically detected from 2400 to 115200 bps on USB and AUX interfaces
Remote Network Access Available through Microedge Smart-Hub
Battery and Power
Internal Battery Built-in 3.6V Lithium Battery.
Battery Life Up to 10 years at a 1-minute sampling interval, depending on usage and operating conditions
External Power 5 VDC through USB
Software
Software SiteView (Sold separately)
Functions Logger configuration, data download, graphing, real-time monitoring, custom calibration, custom equations, alarm configuration, and data analysis
Operating Systems Windows 8, 10 and 11
Computer Requirement 1.0 GHz or faster processor; 1 GB RAM or higher; 10 GB available storage or higher
Required Interface At least one available USB port
Physical Specifications
Enclosure Material Aluminum
PCB Protection Conformal coating.
Dimension 88 X 64.2 X 24 mm (3.46 X 2.53 X 0.95 inches)
Weight 200g
Mounting Integrated holes for wall or equipment mounting
LED Indicators
The tri-color status LED can be disabled to reduce power consumption.
Green Indication Normal sampling
Red Indication Alarm condition
Amber Indication Low battery
Excitation Control
The A2/E terminal can be configured as an excitation-control output for controlling power to an externally powered sensor or device. The excitation warm-up delay is programmable from: 10 to 240 seconds in 10-second increments
Operating Environment
Operating Temperature -40 ~ +70 °C (-40 °F ~ 158 °F)
Operating Humidity 0 ~ 95% RH, non-condensing
Clock Accuracy ±1 mintue per month
Approval CE, FCC

Logger Memory Capacity

Sampling Interval Enabled Channel Logging Capacity
1 minute 1 8 years
1 minute 2 4 years
1 minute 8 1 year
10 seconds 1 485 days
10 seconds 2 242 days
10 seconds 8 60 days
1 second 1 48 days
1 second 2 24 days
1 second 8 6 days
100 milliseconds 1 4 days
100 milliseconds 2 2 days
100 milliseconds 8 14.4 hours

  • $488.00(USD)

Tags: thermistor data logger, temperature data logger, 7 channel thermistor logger, multi-channel thermistor logger, 10k NTC thermistor, NTC thermistor data logger, resistance data logger, resistance measurement, USB data logger, temperature recorder, LPTH-1, SITE-LOG